The 7.1.2 critical release includes a patch to the 18R2 with the following fix:
- Within an optimization change to 6.1.4, an issue was introduced where a script may not fire specific cues due to logic error in our firmware code. This was reported by one customer on Oct. 7th and would only occur in some cases of specific module and cue timing.
This is a critical release and only affects the cobra.s19 file on the 18R2 and should be patched immediately.
To update your 18R2, please follow the following simple steps:
- Download the 7.1.2 cobra.s19 file attached to this article.
- Place cobra.s19 file into the root direction of a USB drive.
- Insert USB drive into the 18R2 while off.
- Hold SYNC and power on 18R2. The LEDS will circle as the firmware is updated.
- Once done, the unit will re-start and 7.1.2 will appear. Remove the USB drive.
- You can re-start the 18R2 to re-confirm 7.1.2 appears.
- You are done and the patch has been successfully applied.
Comments