COBRA Firmware Version 6.1.2 Release

The COBRA 6.1.2 release includes the following fixes. Note that this release requires an update to the .s19 file on the 18R2, 36M/72M and Audio Box.

Please also make sure to update your COBRA Control Panel from Google Play.

  • 18R2 / Control Panel - Jump to re-enabled in Control Panel for timed and STEP events
  • 18R2 / Control Panel - Elapsed time showing incorrectly when jumping is performed
  • 18R2 / Control Panel - Changing firing mode now supported from Control Panel
  • Audio Box - Audio skipping may occur if SMPTE is used with 18R2 together with the Audio Box
  • Control Panel Gen 2 - The UI may display a 36M or 72M’s key state momentarily in the wrong position. This only affects the 36M and 72M modules.
  • 18M Hardware B - When initiating a STEP command from the 18R2 from a scripted show, if a module does not receive the STEP command, it’s possible an event may fire late and eventually re-align once the heartbeat from the 18R2 is received.

To update your 18R2, please use the following steps:

  1. Download the 6.1.2 cobra.s19 file attached to this article.
  2. Place cobra.s19 file into the root direction of a USB drive.
  3. Insert USB drive into the 18R2 while off.
  4. Hold SYNC and power on 18R2. The LEDS will circle as the firmware is updated.
  5. Once done, the unit will re-start and 6.1.2 will appear. Remove the USB drive.
  6. You can re-start the 18r2 to re-confirm 6.1.2 appears.
  7. You are done and the patch has been successfully applied.

To update your 36M/72M, please use the following steps:

  1. Download the 90M.S19 and 90MB.s19 files attached to this article.
  2. Move the S19 files to your USB Drive.
  3. Insert the USB Drive into the 36M/72M while the unit is OFF.
  4. Hold SYNC and power on the unit.
  5. The LEDs on the module will rotate side to side around for a few seconds.
  6. After the LEDs stop, power the unit off and back on again to confirm 6.1.2 has been successfully loaded onto the unit.

To update your Audio Box, please use the following steps:

  1. Download the S19 files attached to this article.
  2. Move the S19 files to your USB Drive.
  3. Insert the USB Drive into the Audio Box while the unit is OFF.
  4. Hold SYNC and power on the unit.
  5. The SYNC LED on Audio Box will flicker for a few seconds.
  6. After the SYNC LED flickering stop, power the unit off and back on again.

To update your 18M and 6M using the COBRA Wireless Reprogrammer, please use the following steps:

  1. Download the COBRA Reprogramming software
  2. Follow the updating steps found in How to Upgrade COBRA Firmware
Was this article helpful?
4 out of 7 found this helpful

Comments

0 comments

Please sign in to leave a comment.

Articles in this section

See more
Our Support Team Hours:
We can be reached by phone at 518-741-4300 or email help@cobrafiringsystems.com
Emergency Shoot Site Support
COBRA offers a 24-hour support system for on-site emergencies. If you are on a shoot site and encounter a show-stopping issue, please reach out to us via phone at 929-930-6868.