Scott Smith
Articles
-
COBRA Firmware Version 6.1.1 Critical Release
The 6.1.1 critical release includes a patch to the 18R2 that prevents modules from firing if the script's first event is a STEP event and all other events in the script are timed events. If your sc...
-
Firmware Compatibility Guide
The COBRA firing systems ecosystem consists of many devices including the 18R2, 18M, 36M, 72M, 6M, and Audio Box. Firmware is the embedded software in our hardware that gives life to the device. CO...
-
COBRA Firmware Version 7.0.1 BETA Release
The COBRA 7.0.1 BETA release introduces some larger new features as explained below. Please note that several of these features including module and event group disabling, and multiple script firin...
-
What is the number that appears when the TEST/ARM LED become solid?
When the TEST/ARM LED light is solid, the total number of devices that are on, and communicating with the 18R2 are displayed on the upper 7-segment display. All devices, including the 18M, 36M, ...
-
COBRA Firmware Version 6.1.0 Stable Release
The 6.1.0 stable release candidate includes the following minor improvements and bug fixes. Note that all improvements and bug fixes are also included within the 7.0 release. Total Events in COBRA...
-
I already own a booster, can this be installed in to the Command Center?
Yes, you can install your existing booster into the Command Center. Please see the COBRA Command Center Installation Guide for assistance.
-
What information is shown on the bottom two 7-segment display?
The information shown on the bottom 7-segment display window includes: When the device is on, but not firing, the time interval between cues when executing an auto-fire sequence. If an error occ...
-
How do I pause and resume a script while running?
The ARM/PAUSE (some 18R2 Controllers only display ARM) button on the 18R2 will pause or resume the script while it is running. When you pause the script by pressing the ARM/PAUSE button, the 18R2 w...
-
What timing resolution does COBRA support, and does this vary across firmware and hardware versions?
Firmware versions 5.0.0 and higher support firing down to 1/100th of a second; 4.0.0 and lower is limited to 1/10th of a second firing resolution. 18M Hardware A does not support 1/100th of a sec...
-
What is the difference between a channel and address?
The channel is assigned to a module by the operator and can be any changed to any channel number you desire. An address is a unique identifier assigned by the 18R2 to each module and other devices ...