Can I fire e-match/MJG Initiators/Talons/Clip-on Igniters on the same module?

Yes, you can use the same module to fire E-match igniters, MJG initiators, and Talon/Clip-on igniter clips. If you are using Talon/Clip-on igniter clips, make sure your module is in Talon/Clip-on Igniter mode and that you always have at least a two-second time gap between firing cues on the same module. The purpose of this is to prevent a shorted e-match on one cue causing a subsequent cue to not fire as the electricity is going through the shorted cue (path of least resistance) while the cues are firing in an overlapping manner. To learn more about the firing mode and how to change to Talon/Clip-on Igniter mode, please see the Firing section of the 18R2 Pro Remote User Guide.

For more information on igniter choices, please see Ignite Right.