Are there specific USB drives that are compatible with the 18R2 when loading scripts?
We highly recommend using the COBRA certified USB drive. However, if you decide to use a different USB drive, we recommend a 2.0, low GB version such as the SanDisk Cruzer 2.0; 8 GB or 16 GB. You c...
-
What types of external power do COBRA Modules support?
COBRA supports external 12-24V DC input. If you are using external power, you will need to set the module to the correct Voltage Mode so the module is aware of the input voltage in order to properl...
-
I am trying to load a script, but am receiving error codes, how can I fix this?
If you are seeing error codes when you are attempting to load your script there could be a few reasons that may cause this. To correct the error it is important to note all information that the con...
-
Can I upgrade the firmware on my 18M?
Yes, you can upgrade the firmware on your 18M by using COBRA's reprogramming software. We provide the firmware updates and the reprogramming software free of charge; however, you do need to purchas...
-
If I power off my 18R2 Controller while the script is running, will it remember its place once powered back on?
If the 18R2 Controller powers off during a script, the modules will continue for up to 60 seconds, depending on firmware, before stopping. Upon powering back on, the 18R2 does not resume the scri...
-
I am having trouble syncing my module to the 18R/18R2; what should I do?
Please watch our video on How to Sync a Device to your Controller. If the SYNC LED is already blinking on your device in response to your remote, your units are already synced and do not need to be...
-
How fast can I fire cues on the 18M?
If using an 18M with B hardware, you can fire cues at 1/100th of a second from module to module. If using an 18M with hardware A, you can fire cues at 1/10th of a second. To see which version of th...
-
When I start up my 18M, what are the sequence of numbers / information appearing before the channel displays?
When your COBRA 18M firing module boots up, the module displays essential information to the operator. Information like the module's battery life and the firmware version is displayed during this p...
-
What is the difference between 1P and 2P during the 18M startup sequence?
When using 9V batteries the firing module uses those three 9V batteries to run two separate internal systems. The first battery, indicated by 1P, powers the operation of the module including the tr...
-
I cannot change the channel on my 18M; why is this?
The 18M uses bump protection on the channel buttons to prevent an accidental channel change while on a shoot site. This bump protection may appear to cause a minor delay in changing the channel; ho...